Illegal Address for field 'CN_Proc_Name' in script 'GetProcinfo'. Script Terminated
Symptoms
When attempting to save a new note, you encounter the following error:
“Illegal Address for field 'CN_Proc_Name' in script 'GetProcinfo'. Script Terminated”
Reason(s)
The following are the possible reasons why this error populated:
- The Collections Management Stored Procedures are not located in the data subfolder of the Microsoft Dynamics GP code folder.
- The Windows User does not have proper permissions to the folder containing the Collections Management Stored Procedures.
Resolution
These stored procedures should be located in the data subfolder of the Microsoft Dynamics GP Folder usually available at the following location:
C:\Program Files (x86)\Microsoft Dynamics\GP 2010 or GP2013 or GP 2015 \Data
So if these two stored Procedures:
CNPROCS.dat and CNPROCS.idx
are located in any other folder ( for example, the GP folder
C:\Program Files (x86)\Microsoft Dynamics\GP 2010 or GP2013 or GP 2015,
they should be moved to the Data folder C:\Program Files (x86)\Microsoft Dynamics\ GP 2010 or GP2013 or GP 2015\Data)
to address this issue
Step 1
Please log out of GP.
Step2
Please go to your Microsoft Dynamics Folder, by default found at the following path, if not please find your dynamics folder and look for your data folder.
Path: C:\Program Files (x86)\Microsoft Dynamics\GP2013\Data
If the CNPROCS.dat and CNPROCS.idx can be located in any other folder ( for example, the GP folder
C:\Program Files (x86)\Microsoft Dynamics\GP 2010 or GP2013 or GP 2015,
they should be moved to the Data folder C:\Program Files (x86)\Microsoft Dynamics\ GP 2010 or GP2013 or GP 2015\Data)
NOTE: If the files are already located in the appropriate folder, ensure that all users have ‘Full Control’ permissions to this folder.
Step3
Please access the Collections Installation and Registration Window and click on
- “Create/ Upgrade Tables “
- “Get Registration info”
- “Install Stored Procedures “